A concrete moisture test tells you whether a slab is dry enough for the flooring going on it — or whether a floor has actually dried after a leak. Here is what the two standard methods measure, how a test is set up, and how results are read, in plain language.
Probes are set in drilled holes and read once the hole has reached equilibrium. It reads moisture at depth, where adhesive bonds — the method most flooring manufacturers now reference.
ASTM F2170 testingA sealed calcium chloride dish on bare concrete measures moisture vapor coming off the surface, reported in lb/1,000 sq ft/24 h against the product limit.
ASTM F1869 testingThe flooring and adhesive installation instructions state the slab moisture limit and which ASTM method it is based on. That decides the test — not the tester's preference.
The space should be at the temperature and humidity it will normally operate at before testing — HVAC running, windows and doors closed. Readings taken in an open, unconditioned shell don't describe the slab the floor will sit on.
A non-destructive meter survey shows wet and dry zones across the slab. Meters are for screening and choosing locations; their readings are comparative and don't replace the ASTM numbers a flooring warranty is written against.
For ASTM F2170, holes are drilled into the slab and relative humidity probes are set inside them. For ASTM F1869, a calcium chloride dish is sealed under a dome on clean, bare concrete.
Both methods need a waiting period before results are valid, so most projects take two visits: one to set the test and one to take readings.
Each reading is compared with the written limit for the specific flooring and adhesive. If a location is over the limit, options usually include more drying time, a moisture mitigation system, or a product rated for higher moisture — per the manufacturer.
Need the number of test locations? Use the free test-count calculator.
A concrete moisture test measures how much moisture a slab holds or releases, so it can be compared with the flooring or adhesive manufacturer's limit before installation or after water damage. The two standard methods are ASTM F2170 (relative humidity inside the slab) and ASTM F1869 (calcium chloride moisture vapor emission from the surface).
Use the method your flooring and adhesive instructions name. ASTM F2170 uses probes in drilled holes to measure relative humidity inside the slab and is the method most manufacturers now reference. ASTM F1869 measures moisture vapor coming off the prepared surface. If the instructions list both, testing both gives the fullest picture.
Both ASTM F2170 and F1869 call for at least three tests for the first 1,000 sq ft, plus one more for each additional 1,000 sq ft. The free calculator on eylark.com estimates the count for your slab area.
No. Non-destructive meters are useful for moisture mapping and choosing where to test, but their readings are comparative. They do not produce the RH or emission-rate numbers that flooring warranties are written against.
Most projects take two visits: one to set the test and one to take readings after the required waiting period. The written report is issued after readings are taken.
EYLARK's ASTM F2170 or F1869 testing starts at $650, a second method on the same visit is $250, and the Platinum two-visit program is $1,200. Prices are flat inside the Southern California service area, with no mileage charge.
Test locations, the test method used, the readings, ambient and site conditions, photographs, and a comparison with the flooring or adhesive manufacturer's moisture limit when one is available. Results apply to the tested locations at the time of testing.
General information only. Always follow the flooring and adhesive manufacturer's written requirements and the full published ASTM procedures.
Last updated: November 17, 2026.